@file SCD4x.h
@author F. Thiebolt
@author F.Thiebolt
@license
This is part of a the neOCampus drivers library.
......@@ -45,7 +45,9 @@
/* scd4x commands
* Note:
* - 1ms min. delay between two commands
* Measurement is either 5s or 30s (normal vs low-power modes)
* It does not start a new measurement till you don't readout the values
* ==> using automatic measurement ought not to consume more power :s
* - most commands need a 1ms execution time
* - CO2, temp and humidity are measured and sent in a single 9bytes frame
* 16bits C02 + CRC + 16bits T + CRC + 16bits RH + CRC
......@@ -55,7 +57,7 @@
enum class scd4xCmd_t : uint16_t {
// basic commands
start_periodic_measurement = 0x21b1, // 5000ms measurement delay
start_periodic_measurement = 0x21b1, // execution time: none. 5000ms measurement delay (i.e read_measurement)
read_measurement = 0xec05, // execution time: 1ms
stop_periodic_measurement = 0x3f86, // execution time: 500ms
......